<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-02 08-19-47
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 68 dBuV Classic
Pilot RDS Phase Difference
6.9 kHz 3.1 kHz 82 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 62 kHz 19040 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-4,4 dBr 0,82 dBr 3,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Alfred Brendel (Piano) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 62 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2024/08/02 8.18.44 Total samples: 19040 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 3,7 dBr MIN: -4,4 dBr AVE: 0,82 dBr % above 12,2 dBr: 0,0 Last value: 1,1 dBr (2024/08/02 8.18.44) 08.04 08.06 08.08 08.10 08.12 08.14 08.16 08.18 -4 -2 0 2 4 Pm [dBr]